DC/DC Converter
TDU 1 Series, 1 Watt
•
Compact 1 Watt converter in DIP-8
package
•
•
•
Continuous short circuit protection
•
•
I/O isolation 1’500 VDC
•
•
Efficiency up to 83%
Unregulated outputs
Operating temperature range
-40 to +85 °C without derating
Input voltage ranges (±10%):
5, 12, 24 VDC
3-year product warranty
The TDU 1 series consists of a set of isolated 1 Watt DC/DC converters with
unregulated outputs in a compact DIP-8 package. They are designed to offer a
compact low-cost alternative to regulated series with no concession on quality
and lifetime. They feature a continuous short circuit protection circuit, I/O-isolation of 1500 VDC and an operating temperature range from –40°C to 85°C
without derating. The compact dimensions of these converters make them an
ideal solution for many space critical applications in communication equipment,
instrumentation and industrial electronics.
Models
Order Code
TDU 1-0511
TDU 1-0512
TDU 1-0513
TDU 1-1211
TDU 1-1212
TDU 1-1213
TDU 1-2411
TDU 1-2412
TDU 1-2413
www.tracopower.com
Input Voltage
Output Voltage
Output Current
Efficiency
Range
nom.
max.
typ.
4.5 - 5.5 VDC
(5 VDC nom.)
5 VDC
200 mA
80 %
12 VDC
84 mA
82 %
15 VDC
67 mA
83 %
5 VDC
200 mA
79 %
12 VDC
84 mA
81 %
15 VDC
67 mA
82 %
5 VDC
200 mA
78 %
12 VDC
84 mA
80 %
15 VDC
67 mA
81 %
10.8 - 13.2 VDC
(12 VDC nom.)
21.6 - 26.4 VDC
(24 VDC nom.)
September 20, 2023
Page 1 / 4
TDU 1 Series, 1 Watt
Input Specifications
Input Current
- At no load
5 Vin models:
12 Vin models:
24 Vin models:
5 Vin models:
- At full load
12 Vin models:
24 Vin models:
Surge Voltage
5 Vin models:
12 Vin models:
24 Vin models:
5 Vin models:
12 Vin models:
24 Vin models:
Recommended Input Fuse
Input Filter
30 mA typ. / 45 mA max.
17 mA typ. / 25 mA max.
10 mA typ. / 15 mA max.
256 mA max. (5 Vout model)
250 mA max. (12 Vout model)
247 mA max. (15 Vout model)
108 mA max. (5 Vout model)
106 mA max. (12 Vout model)
104 mA max. (15 Vout model)
55 mA max. (5 Vout model)
54 mA max. (12 Vout model)
53 mA max. (15 Vout model)
9 VDC max. (1 s max.)
18 VDC max. (1 s max.)
30 VDC max. (1 s max.)
600 mA (slow blow)
250 mA (slow blow)
150 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal Capacitor
Output Specifications
Voltage Set Accuracy
Regulation
Ripple and Noise
Capacitive Load
Minimum Load
Temperature Coefficient
Short Circuit Protection
- Input Variation (1% Vin step)
- Load Variation
- 20 MHz Bandwidth
±3% max.
1.5% max.
See application note: www.tracopower.com/overview/tdu1
100 mVp-p max.
220 µF max.
2 % of Iout max.
±0.02 %/K max.
Continuous, Automatic recovery
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
External filter proposal:
EMS Immunity
- Electrostatic Discharge
Air:
Contact:
- RF Electromagnetic Field
- EFT (Burst) / Surge
External filter proposal:
- Conducted RF Disturbances
- PF Magnetic Field
Continuous:
EN 55032 class B (with external filter)
EN 55032 class B (with external filter)
www.tracopower.com/overview/tdu1
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
www.tracopower.com/overview/tdu1
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 30 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
95% max. (non condensing)
–40°C to +85°C (without derating)
+95°C max.
–50°C to +125°C
Natural convection (20 LFM)
- Operating Temperature
- Case Temperature
- Storage Temperature
Cooling System
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 2 / 4
TDU 1 Series, 1 Watt
Switching Frequency
Insulation System
Isolation Test Voltage
Creepage
Clearance
Isolation Resistance
Isolation Capacitance
Reliability
Washing Process
Environment
- Input to Output, 60 s
- Input to Output, 1 s
- Input to Output
- Input to Output
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
- Vibration
- Mechanical Shock
- Thermal Shock
Housing Material
Base Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Environmental Compliance - REACH Declaration
- RoHS Declaration
20 - 95 kHz (Royer)
50 kHz typ. (Royer)
Functional Insulation
1'500 VDC
1'800 VDC
1.38 mm min.
1.38 mm min.
1'000 MΩ min.
20 pF typ.
5'000'000 h (MIL-HDBK-217F, ground benign)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
IPC-9592B
IPC-9592B
IPC-9592B
Non-conductive Plastic (UL 94 V-0 rated)
Non-conductive Plastic (UL 94 V-0 rated)
Silicone (UL 94 V-0 rated)
Phosphor Bronze (C5191)
Nickel (1 µm min.)
Tin (3 - 5 µm), matte
Plastic Case
PCB Mount
THD (Through-Hole Device)
DIP8
Lead-Free Wave Soldering
260°C / 4 s max.
2.1 g
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: No Exemptions
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tdu1
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 3 / 4
TDU 1 Series, 1 Watt
Outline Dimensions
Pinout
8.0 (0.31)
Function
1
in
4
+Vin
5
+Vout
7
out
3.1 (0.12)
0.4 (0.02)
Pin
2.54 (0.10)
Ø0.50 (0.02)
2.6 (0.10)
7.62 (0.30)
BOTTOM VIEW
5
5.08 (0.20)
12.7 (0.50)
1.3 (0.05)
7
10.2 (0.40)
4
7.62 (0.30)
1
Dimensions in mm (inch)
Tolerances: x.x ±0.5 (±0.02)
x.xx ±0.25 (±0.01)
Pin tolerances: ±0.05 (±0.002)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. September 20, 2023
Page 4 / 4
很抱歉,暂时无法提供与“TDU 1-1211”相匹配的价格&库存,您可以联系我们找货